20230615 - FELIXFood V1.5 - Switch - V1.5.03 - 1555
- First setup for variable Z-probe height

20230615 - FELIXFood V1.5 - Switch - V1.5.03 - 1405
- Changed the values for Z-probe switching

20230616 - FELIXFood V1.5 - Switch - V1.5.03 - 0758
- Changed the data type to float for the variable Z-probe height
- Changed the eeprom positions to 1110 for left and 1116 for right

20230616 - FELIXFood V1.5 - Switch - V1.5.03 - 1401
- Made sure that the left and right probe height values do not reset during a eeprom reset

20230616 - FELIXFood V1.5 - Switch - V1.5.03 - 1538
- Removed the save to eerpom

20230619 - FELIXFood V1.5 - Switch - V1.5.03 - 1028
- Changed the order for the XYZ calibration so the offset is reset before homing

20230619 - FELIXFood V1.5 - Switch - V1.5.03 - 1544
- Changed the XYZ script so the X reset value is the one set in the configuration file so the script is modulair for Food and Bio

20240220 - FELIXFood V1.5 - Switch - V1.5.04 - 0923
- Enabled the ext0 and ext1 setfloat in CustomEventsImpl.h

20240220 - FELIXFood V1.5 - Switch - V1.5.04 - 1037
- Changed the "cardcenter" values for auto XYZ calibration to X=84 and Y=48

20240220 - FELIXFood V1.5 - Switch - V1.5.04 - 1439
- Created M4241 to test wich value is needed for Z-probe calibration.

20240220 - FELIXFood V1.5 - Switch - V1.5.04 - 1512
- Changed the probe calibration so it will save the value the left and right probe values
- Created a eeprom value for a probe corretion (0.6 for food)

20240220 - FELIXFood V1.5 - Switch - V1.5.04 - 1554
- Disabled the probe correction eeprom value for troubleshooting
 
20240221 - FELIXFood V1.5 - Switch - V1.5.04 - 0805 (Failed compiling)
- Changed the M4240 macro to see if not writing to the eeprom will fix eeprom corruption

20240221 - FELIXFood V1.5 - Switch - V1.5.04 - 0810
- Included "EEPROM::storeDataIntoEEPROM(false)" in M4240 to see if that fixes the error

20240221 - FELIXFood V1.5 - Switch - V1.5.04 - 0917
- Cleaned up customeventsimp.h
- Enabled probe correction variable
- Included M4240 S1 in start scripts so the probe value of the left syringe is picked at startup
- Included probe heihgt set to the calculated value in M4213

20240221 - FELIXFood V1.5 - Switch - V1.5.04 - 0952
- Changed the XYZ calibration location to X=82 and Y=51
- Changed the XYZ trashold to 0.3 because the pocket is 0.6 in the glass plate

20240307 - FELIXFood V1.5 - Switch - V1.5.05 - 1422
- Changed the auto XYZ script so that it will correctly change the probe height values during the calibration
- Changed M4213 to it will first load the Z-probeheight
- Removed the float before Zheight